Saturday, November 8, 2014

Car Battery 12v Charger

The usual chargers of battery automotive, are simple and cheap appliances that charge continuously the battery, with a rythm of few amperes, for the time where the appliance is ON. If the holder do not close in time the charger, the battery will overcharge and her electrolytic faculty are lost with evaporation or likely exists destruction of her elements. The charger of circuit exceeds these faults. It checks electronic the situation of charge of battery and it has circuit of control with retroaction, that forces the battery charge with biggest rythm until charge completely.
Circuit diagram:

Car Battery 12v Charger Circuit Diaram
When charge completely, it turns on one RED led (LD2). The charger has been drawn in order to charge batteries of 12V, ONLY. What should watch it from what it manufactures the circuit, they are the cables that connect the transformer with the circuit and in the continuity the battery, should they are big cross-section, so that heat when it passes from in them the current of charge and also they do not cause fall of voltage at the way of current through them.
Adjustment
After assembling of the circuit, adjust TR1 to null value, power-up and make the following adjustments :-
  1. Without connecting the battery check that the 2 LED?s are turned on.
  2. Connect a car battery to the circuit and check that LD2 is OFF and a current (normally 2A to 4A) is flowing to the battery.
  3. Adjust TR1 until LD2 turns ON and the charge current is cut.
  4. Adjust TR1 to null value and charge the battery using the hydrometer technique (if you do not have or do not know how to use a hydrometer, then use a good condition battery and charge).

Carefully adjust TR1 so that LD2 begins to turn ON and the charge current falls to a few hundred milliamps (mA). If TR1 is set correctly then in the next round of charging you will noticed LD2 begin to flicker as the battery is being charged. When battery is completely charged, LD2 turns ON completely.TR1 does not need further adjustment anymore. Q1 is connected in line with the battery and is fired by R3, R4 and LD2. The R2, C1, TR1 and D2 sense the voltage of the battery terminal and activate Q2 when the voltage of the battery terminal exceeds the value predetermined by TR1.

When an uncharged battery is connected, the terminal voltage is low. Under this circumstance, Q2 is turned OFF and Q1 is fired in each half cycle by R3, R4 and LD2. The Q1 functions as a simple rectifier and charges the battery. If the battery terminal voltage is increased above the level that had been fixed by TR1, then Q2 shifts the control of Q1 gate. This deactivates Q1 and cuts off the current supply to the battery and turns LD2 ON indicating that the charge has been completed. Q1 and bridge rectifier GR1 should be mounted on heatsinks to prevent overheating. M1 is a 5A DC ammeter to measure the charge current
Read More..

Monday, September 1, 2014

Simple Battery charger Wiring diagram Schematic

This is a simple Battery charger schema diagram. A diac is used in the gate schema to provide work for the signal being applied to the gate. R1 a threshold level for firing the triac. C3 and R4 is selected to limit the maximum charging cur-provide a transient suppression network Rl, rent at full Totation of R2. R2, R3, Cl, and C2 provide a phase-shift net.


Simple Battery charger Circuit Diagram




Simple Battery charger Circuit Diagram
Read More..

Friday, August 29, 2014

Intelligent Battery Charging Wiring diagram Schematic

Intelligent Battery Charging Circuit Diagram. Intended for a Nicad application this charging schema can be used with a wide range of batteries. A low-battery detector is intended. The trip voltage is set via the 500-kQ pot. Select Rc for the battery you intend to use.

Intelligent Battery Charging Circuit Diagram

Intelligent

Read More..

Thursday, August 28, 2014

Advanced Linear NiMH NiCd Fast Battery Charger

This is a simple Batteries charger for NiMH/NiCd.It Requires No Microcontroller or any Firmware.Linear Technology Corporation introduces the LTC4060, an autonomous 1- to 4-cell, 0.4A to 2A linear NiMH and NiCd battery charger. The LTC4060 includes all the functions required for a battery charger schema, operating without the aid of a microcontroller or firmware. The design is simple and needs only three passive components. The LTC4060 also eliminates the need for a sense resistor and blocking diode, which increases efficiency and lowers the solution cost. This IC is targeted at applications including portable medical equipment, automotive diagnostic systems and industrial/telecom test devices. 
Features
  • Complete Fast Charger Controller for Single, 2-, 3- or 4-Series Cell NiMH/NiCd Batteries
  • No Firmware or Microcontroller Required
  • Termination by –?V, Maximum Voltage or Maximum Time
  • No Sense Resistor or Blocking Diode Required
  • Automatic Recharge Keeps Batteries Charged
  • Programmable Fast Charge Current: 0.4A to 2A
  • Accurate Charge Current: ?5% at 2A
  • Fast Charge Current Programmable Beyond 2A with External Sense Resistor
  • Automatic Detection of Battery
  • Precharge for Heavily Discharged Batteries
  • Optional Temperature Qualified Charging
  • Charge and AC Present Status Outputs Can Drive LED
  • Automatic Sleep Mode with Input Supply Removal
  • Negligible Battery Drain in Sleep Mode: <1?A
  • Manual Shutdown
  • Input Supply Range: 4.5V to 10V 

    Read More..

    Battery Charger for 12v SLA Project

    Before we go into the operation of the SLA Battery Charger schema, there are a number of points we need to cover about the care and use of Sealed Lead Acid batteries. The words Sealed Lead Acid covers a number of batteries that do not have a "filling hole."

    You cannot get to the electrolyte and the battery can be used in any position. This discussion also covers AGM batteries (Absorbed Glass Mats) that have a separator between the plates and the electrolytic is thick and will not spill.

    Another type: GEL CELL and FLOODED LEAD ACID all have the same or similar charging requirements and can be used with this charger because it is a low-current charger (about 300mA) and will not damage anything. It also has the feature of providing pulses to the battery when 13.4v is detected and this will eventually fully charge any battery and keep a it fully charged for months, and even years.

    Firstly, Sealed Lead Acid batteries must be charged, discharged and stored very carefully. We normally think batteries can be stored for months (if not years) and they will be available for immediate use. This is not the case with SLA batteries.

    If you store a NEW, full charged SLA battery for 6 months or more, you will find it may be fully discharged.
    You may also find you cannot charge it!!   It may be worthless. Thats how delicate SLA batteries are. They must be charged on a regular basis to prevent them discharging to a very low voltage level.

    If the terminal voltage of a SLA battery is allowed to go below 8v, a process called SULPHATION starts to cover the surface of the plates and prevents the battery being re-charged. The internal resistance of the battery increases and it becomes useless.


    HOW THE CIRCUIT WORKS


    The schema consists of 5 building blocks:

     The schema does not turn on until a battery is connected across the terminals as shown in the diagram. (A push switch has been provided to start the schema when a totally flat battery is fitted.) This action turns on the PNP transistor in the "Turn ON" block. The resistance between the collector-emitter terminals decreases and the indicator LED comes on.

    The path to the bottom rail of the schema goes through a signal diode, the gate-cathode junction of the SCR and through two 1R8 resistors in parallel. This is why the LED illuminates.

    MUST USE AC PLUG PACK
    Before we go any further, the schema works on an AC plug pack. It must be an AC supply as we do not want any electrolytics to be present on the power rail as this will allow a very high charge-current to flow and possibly damage the SCR. A DC supply will not allow the SCR to turn off, as it turns off when the current through it falls to zero.

    THE CIRCUIT IS A HALF-WAVE RECTIFIER!
    The schema is actually a half-wave rectifier. It only charges the battery on every half cycle. The plug pack doesnt like this as it leaves residual flux in the core of the transformer and causes it to overheat. But thats the only drawback with the schema.

    The SCR turns on during each half cycle and current flows into the battery. A voltage is developed across the two 1R8 resistors (in parallel) and this voltage is fed into the 47u electrolytic. It charges and turns on the BC547 transistor. The transistor robs the SCR of gate voltage and the SCR turns off. The energy in the 47u feeds into the transistor but after a short time it cannot keep the transistor turned on.

    The transistor turns off and the SCR switches on and delivers another pulse of current to the battery. As the battery charges, its voltage increases and this is monitored by the "Voltage Monitor" block. The schema is very complex and one way to look at the operation is to consider the top rail as a fixed rail and as the battery voltage increases, the rail connected to the negative terminal of the battery is pushed down.

    This lets you see how the "Turn On" transistor is activated and how the "Voltage Monitor" components create voltage drops across each of them. The "Voltage Monitor" components consist of a transistor and zener diode as well as an 8k2 resistor, the 1k pot, a 1k5 resistor, a 150R resistor and a signal diode. The signal diode is actually part of the flasher schema and we discuss its operation later.

    As the voltage across the battery increases to 13.4 volts, each resistor in the "voltage detecting network"  will have a voltage drop across it that corresponds to the resistance of the resistor. The diode will have a constant 0.7v across it. The voltage on the wiper of the pot will be about 3.25v and the voltage across the zener will be 10v. This leaves 0.6v between the base and emitter of the Voltage Monitor transistor.

    This voltage is sufficient to turn the transistor ON.
    When the Voltage Monitor transistor turns ON, it robs the "Turn On" transistor of base-emitter voltage and the schema turns off.

    The SCR has only two states: ON and OFF.
    During the half-cycle when it is turned on, the battery gets a high pulse of current and the current is only limited by the capability of the plug pack. There are no electrolytics to allow very high pulses of current to be delivered and this is fortunate as the SCR is only a 0.8 amp device, but will endure surges of 10amp for half a cycle.

    Whenever the SCR is triggered into conduction during the half cycle of its operation, it remains in conduction until the voltage delivered by the plug pack falls to zero. This is when the SCR turns off. When the plug pack delivers a negative voltage to the top rail and a positive voltage to the lowest rail, the SCR is not triggered into conduction and none of the components in the schema deliver current to the battery. The SCR delivers current for a few half-cycles and then it is turned off for a few cycles. This is how the average current delivered to the battery is controlled.

    The schema is designed to deliver about 300 - 400 mA average charge-current. The maximum value is determined by the 1R8 resistors. They do not allow any more than 900mA to flow during a half-cycle and if this current flows, the lower 47u is charged and the lower transistor turns on to prevent the SCR turning on.
    When the battery is fully charged, the indicator LED begins to flash.

    The flashing is produced by the 2k2 resistor and 47u (connected to the voltage monitor section). When the battery is charging, the 47u is charged via the diode connected to the BC557 transistor and through the 150R and signal diode to the negative of the battery.

    When the battery is fully charged, the Voltage Monitor section turns ON and turns off the "Turn ON" section.
    This removes the voltage on the positive side of the 47u and the positive side is brought to the negative rail via the 2k2 resistor. This brings down the negative side of the 47u and the 150R resistor is  allowed to drop below the negative rail due to the presence of the diode, as the diode becomes reverse-biased.

    This holds the schema in the "off" condition, as the voltage monitor section sees an extra voltage across it and thinks the battery it is "over-charged."



    The 47u discharges and the schema turns ON to pump a small burst of current into the battery to keep it charged. This is called "Trickle Mode"  or "Pulse Mode."


    HOW TO SET THE POT
    Charge a battery and when the voltage reaches 13.4v, adjust the pot so the LED flashes.


    DEAD BATTERIES
    The schema will not turn on if the voltage of the battery you are charging is less than 4 volts. If you have a good battery that has been totally discharged, you can manually start the charging process by connecting the battery and pressing the button. This will raise the voltage on each cell and the schema will take over in the normal way once the voltage rises more than 4 volts.

    SCR: MCR100     
    type - 6     400v
    current     0.8A
    Max current
    for half cycle     10A

    DONT WASTE YOUR TIME
    If you have a battery that does not charge, even after you have pressed the push button, dont waste your time. If it has been standing for more than 6 months in an uncharged state, it will not charge. This charger is ideal in determining if a battery is able to be charged.

    Just connect it to the charger and monitor the voltage across the battery. If it remains at less than 8v after 1 hour, the battery is scrap. You can easily test a battery by putting a 12v car globe across the terminals. Even a tail light globe will require a current of more than 1 amp to get it to glow and if the battery cannot deliver this current, it is DEAD.

    The only "dead" battery that can be recovered is one that has been connected to equipment and is totally exhausted. The equipment has exhausted the battery. If you charge it within a few weeks, the process of "sulphation" will not have damaged it and it can be fully charged. If the battery is "dead" due to standing for a long time, the chances of recovery are virtually nil.

    Sealed Batteries
    Sealed batteries have the acid either gelled or put into a sponge-like glass mat. They have the advantage/disadvantage of being completely liquid-tight. They can operate in any position, even sideways or upside down, and will not leak acid. Because the electrolyte moves more slowly, these batteries cannot tolerate high rates of charging or discharging for extended periods, although their thinner plates will allow high rates for a short time. Their sealed construction, which makes them ideal for some limited applications, makes it impossible to check individual cell conditions with a hydrometer. Although these cells are "sealed," they do have vents to prevent pressure build-up in case of gassing. Many PV charge controls will push charging voltage too high for sealed batteries. Premature failure will result due to loss of water vapor. We recommend sealed batteries only in situations where hydrogen gassing during charging cannot be tolerated, or the battery is going to be moved and handled a great deal, or in conditions where the battery needs to fit into unique, tight spaces. Boats, UPS computer power supplies, and remote expeditions are the most common uses. Special lower voltage charge controls must be used with these batteries. Life expectancy is two to five years for most AGM (absorbed glass mat) batteries, and five to ten years for the higher quality, but more difficult to manufacture, gel cell batteries. Most sealed batteries are AGM types.


    Here is a Printed Circuit board made by Tom Kelly, one of our readers:


    You can clearly see the track-work under the board and it is easy to copy the layout and produce your own board. The board was produced by Tom Kelly.  You can email him for the file so you can make your own PC board.

    Or you can buy a PCB from Talking Electronics with overlay and tinned solder-lands for $3.00 plus $3.00 postage

    PCB

    PARTS LIST
    12v SLA Battery Charger
    PCB $3.00 plus $3.00 post

    2 - 1R8 0.5watt resistors
    1 - 150R 0.25 watt resistor
    1 - 180R
    1 - 560R
    1 - 1k5
    3 - 2k2
    1 - 3k3
    1 - 4k7
    1 - 8k2
    1 - 1k mini trim pot

    1 - 1n ceramic
    2 - 47u 25v electrolytics

    1 - 5mm red LED

    4 - 1N4148 signal diodes
    1 - 10v 0.25watt zener
    1 - BC 547 transistor
    2 - BC557 transistors
    1 - MCR100-6 SCR
    1 - 1m red lead
    1 - 1m black lead
    2 - alligator clips
    1 - 2m very fine solder

    1 - SLA Battery Charger PCB

    Also required:
    1 - 12v AC transformer (500mA AC)
    1 - power lead
    1 - case


    Sourced by: talkingelectronics
    Read More..

    Monday, August 25, 2014

    Nicad Battery charger easy to make

    Nicad battery charger , this circuit just use transformer not  CT and  3 LEDs lamp. And its very very simple circuit charger . This circuit constant current LEDs to adjust charging current. It uses LEDs that pass a constant  current about 15 mA for an applied voltage range of 2 to 18 Volt.
    They can be paralleled to give any multiple of 15 mA and they light up when current is flowing. The circuit will charge single cell at 15 , 30 , or 45 mA , or cells in series up to the rated supply voltage limit about 14 Volt.
    See schematic below :


    Click to view larger
    Read More..

    Sunday, August 24, 2014

    Low battery detector circuit

    You feel confused to detect wether a battery is low or high, or you want to be notified if the battery and has expired , this circuit can detect if a battery has begun to decrease its strength. Circuit is based on LM4250 IC is able to detect if the battery runs out and will issue a notification signal.
    Read More..

    Friday, August 22, 2014

    Simple Lead Acid Battery Charger 1

    Except for use as a normal Battery Charger, this schema is perfect to constant-charge a 12-Volt Lead-Acid Battery, like the one in your flight box, and keep it in optimum charged condition. This schema is not recommended for GEL-TYPE batteries since it draws to much current. The above schema is a precision voltage source, and contains a temperature sensor with a negative temperature coλficient. Meaning, whenever the surrounding or battery temperature increases the voltage will automatically decrease. Temperature coλficient for this schema is -8mV per °Celcius. A normal transistor (Q1) is used as a temperature sensor. This Battery Charger is centered around the LM350 integrated, 3-amp, adjustable stabilizer IC. Output voltage can be adjusted with P1 between 13.5 and 14.5 volt.

    T2 was added to prevent battery discharge via R1 if no power present. P1 can adjust the output voltage between 13.5 and 14.5 volts. R4s value can be adjusted to accommodate a bit larger or smaller window. D1 is a large power-diode, 100V PRV @ 3 amp. Bigger is best but I dont recommend going smaller. The LM350s adjust pin will try to keep the voltage drop between its pin and the output pin at a constant value of 1.25V. So there is a constant current flow through R1. Q1 act here as a temperature sensor with the help of components P1/R3/R4 who more or less control the base of Q1. Since the emitter/base connection of Q1, just like any other semiconductor, contains a temperature coλficient of -2mV/°C, the output voltage will also show a negative temperature coλficient.

    BatteryThat one is only a factor of 4 larger, because of the variation of the emitter/basis of Q1 multiplied by the division factor of P1/R3/R4. Which results in approximately -8mV/°C. To prevent that sensor Q1 is warmed up by its own current draw, I recommend adding a cooling rib of sorts. (If you wish to compensate for the battery-temperature itself, then Q1 should be mounted as close on the battery as possible) The red led (D2) indicates the presence of input power.Depending on what type of transistor you use for Q1, the pads on the schema board may not fit exactly (in case of the BD140).
    Read More..