DC DC Converter 12V to 24V

This simple circuit is a DC-DC converter that converting up 12V source to a 24V. It can be used to run radios, small lights, relays, horns and other 24V accessories from a 12V vehicle with a maximum draw of about 800mA.



This DC-DC Converter can be used to charge one 12V battery from another, or step up the voltage just enough to provide necessary overhead for a 12V linear regulator. Using one op-amp as a squarewave oscillator to ring an inductor and another op-amp in a feedback loop, it wont drift around under varying loads, providing a stable 24V source for many applications. With a wide adjustment in output this circuit has many uses. 

Parts List
R1-R4,R7-R8 100K 1/4W Resistor 
R5 470 Ohm 1/2W Resistor 
R6 10K Linear Pot 
C1 0.01uF Mylar Capacitor 
C2 0.1uF Ceramic Disc Capacitor 
C3 470uF 63V Electrolytic Capacitor 
D1 1N4004 Rectifier Diode 
D2 BY229-400 Fast Recovery Diode See Notes
Q1 BC337 NPN Power Transistor 
U1 LM358 Dual Op Amp IC 
L1 See Notes 
MISC Board, Wire, Socket For U1, Case, Knob For R6, Heatsink for Q1

DC- DC Converter Notes 
1. R6 sets the output voltage. This can be calculated by Vout = 12 x (R8/(R8+R7)) x (R6B/R6A). 
2. L1 is made by winding 60 turns of 0.63MM magnet wire on a toroidial core measuring 15MM (OD) by 8MM (ID) by 6MM (H). 
3. D2 can be any fast recovery diode rated at greater then 100V at 5A. It is very important that the diode be fast recovery and not a standard rectifier.4. Q1 will need a heatsink.
Read More..

Monday, November 17, 2014

12V to 20V DC converter

DC To DC Converter circuit used to be an alter tegngan voltage DC to DC with different concepts. DC to DC converter circuit +12 V to + /-20V is working to change the battery voltage from 12V DC to 20V DC voltage symmetrical. DC to DC converter circuit is often applied to the power amplifier udio on car audio systems. DC to DC converter circuit uses a TL494 IC as power plsa for the converter. TL494 IC is a PWM controller with an adjustable frequency from 40-60Hz through a potentiometer. Then from the TL494 PWM signal is given to the driver MOSFET inverter TPS2811P to be given to the power inverter with 2 units of MOSFET transistors. Circuit details can be seen in the figure following the DC to DC converter.

DC To DC converter circuit +12 V To + / - 20V

+12V

List Components DC To DC Converter +12 V To + / - 20V
R1, R2 = 10
R3, R4, R6, R7 = 1k
R5 = 22k
R8 = 4.7k
R9 = 100k
C1, C2 = 10000uF
C3, C6 = 47 u
C4 = 10U
C5, C7, C14 = 100n
C8, C9 = 4700u
C12 = 1N
C13 = 2.2u
U1 = TL494
U2 = TPS2811P
Q1, Q2 = FDB045AN
D1-D4 = 1N5822
D5 = 1N4148
FU1 = 10A
L1 = 10U
L2 = ferrite BEAD
RV1 = 2.2k
RV2 = 24k
T1 = TRAN-3P3S
DC To DC converter circuit +12 V To + / - 20V is capable of supplying up to 100W and can power supplying currents up to 3A. In making DC To DC Converter +12 V To + / - 20V has to be careful and cautious because there are parts of DC To DC Converter +12 V To + / - 20V in the form of an AC circuit.
Read More..

Saturday, November 8, 2014

Car Battery 12v Charger

The usual chargers of battery automotive, are simple and cheap appliances that charge continuously the battery, with a rythm of few amperes, for the time where the appliance is ON. If the holder do not close in time the charger, the battery will overcharge and her electrolytic faculty are lost with evaporation or likely exists destruction of her elements. The charger of circuit exceeds these faults. It checks electronic the situation of charge of battery and it has circuit of control with retroaction, that forces the battery charge with biggest rythm until charge completely.
Circuit diagram:

Car Battery 12v Charger Circuit Diaram
When charge completely, it turns on one RED led (LD2). The charger has been drawn in order to charge batteries of 12V, ONLY. What should watch it from what it manufactures the circuit, they are the cables that connect the transformer with the circuit and in the continuity the battery, should they are big cross-section, so that heat when it passes from in them the current of charge and also they do not cause fall of voltage at the way of current through them.
Adjustment
After assembling of the circuit, adjust TR1 to null value, power-up and make the following adjustments :-
  1. Without connecting the battery check that the 2 LED?s are turned on.
  2. Connect a car battery to the circuit and check that LD2 is OFF and a current (normally 2A to 4A) is flowing to the battery.
  3. Adjust TR1 until LD2 turns ON and the charge current is cut.
  4. Adjust TR1 to null value and charge the battery using the hydrometer technique (if you do not have or do not know how to use a hydrometer, then use a good condition battery and charge).

Carefully adjust TR1 so that LD2 begins to turn ON and the charge current falls to a few hundred milliamps (mA). If TR1 is set correctly then in the next round of charging you will noticed LD2 begin to flicker as the battery is being charged. When battery is completely charged, LD2 turns ON completely.TR1 does not need further adjustment anymore. Q1 is connected in line with the battery and is fired by R3, R4 and LD2. The R2, C1, TR1 and D2 sense the voltage of the battery terminal and activate Q2 when the voltage of the battery terminal exceeds the value predetermined by TR1.

When an uncharged battery is connected, the terminal voltage is low. Under this circumstance, Q2 is turned OFF and Q1 is fired in each half cycle by R3, R4 and LD2. The Q1 functions as a simple rectifier and charges the battery. If the battery terminal voltage is increased above the level that had been fixed by TR1, then Q2 shifts the control of Q1 gate. This deactivates Q1 and cuts off the current supply to the battery and turns LD2 ON indicating that the charge has been completed. Q1 and bridge rectifier GR1 should be mounted on heatsinks to prevent overheating. M1 is a 5A DC ammeter to measure the charge current
Read More..

Saturday, October 4, 2014

12V Fan Temperature Controller

this simple design allows|permits an correct speed control of 12V dc fan motors, proportional to temperature. A n.t.c. Thermistor (R1) is employed as temperature sensor, driving two directly coupled complementary transistors wired during a dc feedback circuit. An optional circuitry was added to remotely monitor fan operation and to permit some type of rough speed indication by means that of the increasing brightness of a LED.

Notes:

  • R5 must be set to allow motor just starting at the desired temperature.
  • Any n.t.c. Thermistor in the 6K8 - 22K range value might work, provided R2 value is one/tenth of Thermistors value.
  • R6, R7 and D1 are optional: R7 must be adjusted until the LED glows faintly when the motor is just running.
Read More..

Thursday, August 28, 2014

Battery Charger for 12v SLA Project

Before we go into the operation of the SLA Battery Charger schema, there are a number of points we need to cover about the care and use of Sealed Lead Acid batteries. The words Sealed Lead Acid covers a number of batteries that do not have a "filling hole."

You cannot get to the electrolyte and the battery can be used in any position. This discussion also covers AGM batteries (Absorbed Glass Mats) that have a separator between the plates and the electrolytic is thick and will not spill.

Another type: GEL CELL and FLOODED LEAD ACID all have the same or similar charging requirements and can be used with this charger because it is a low-current charger (about 300mA) and will not damage anything. It also has the feature of providing pulses to the battery when 13.4v is detected and this will eventually fully charge any battery and keep a it fully charged for months, and even years.

Firstly, Sealed Lead Acid batteries must be charged, discharged and stored very carefully. We normally think batteries can be stored for months (if not years) and they will be available for immediate use. This is not the case with SLA batteries.

If you store a NEW, full charged SLA battery for 6 months or more, you will find it may be fully discharged.
You may also find you cannot charge it!!   It may be worthless. Thats how delicate SLA batteries are. They must be charged on a regular basis to prevent them discharging to a very low voltage level.

If the terminal voltage of a SLA battery is allowed to go below 8v, a process called SULPHATION starts to cover the surface of the plates and prevents the battery being re-charged. The internal resistance of the battery increases and it becomes useless.


HOW THE CIRCUIT WORKS


The schema consists of 5 building blocks:

 The schema does not turn on until a battery is connected across the terminals as shown in the diagram. (A push switch has been provided to start the schema when a totally flat battery is fitted.) This action turns on the PNP transistor in the "Turn ON" block. The resistance between the collector-emitter terminals decreases and the indicator LED comes on.

The path to the bottom rail of the schema goes through a signal diode, the gate-cathode junction of the SCR and through two 1R8 resistors in parallel. This is why the LED illuminates.

MUST USE AC PLUG PACK
Before we go any further, the schema works on an AC plug pack. It must be an AC supply as we do not want any electrolytics to be present on the power rail as this will allow a very high charge-current to flow and possibly damage the SCR. A DC supply will not allow the SCR to turn off, as it turns off when the current through it falls to zero.

THE CIRCUIT IS A HALF-WAVE RECTIFIER!
The schema is actually a half-wave rectifier. It only charges the battery on every half cycle. The plug pack doesnt like this as it leaves residual flux in the core of the transformer and causes it to overheat. But thats the only drawback with the schema.

The SCR turns on during each half cycle and current flows into the battery. A voltage is developed across the two 1R8 resistors (in parallel) and this voltage is fed into the 47u electrolytic. It charges and turns on the BC547 transistor. The transistor robs the SCR of gate voltage and the SCR turns off. The energy in the 47u feeds into the transistor but after a short time it cannot keep the transistor turned on.

The transistor turns off and the SCR switches on and delivers another pulse of current to the battery. As the battery charges, its voltage increases and this is monitored by the "Voltage Monitor" block. The schema is very complex and one way to look at the operation is to consider the top rail as a fixed rail and as the battery voltage increases, the rail connected to the negative terminal of the battery is pushed down.

This lets you see how the "Turn On" transistor is activated and how the "Voltage Monitor" components create voltage drops across each of them. The "Voltage Monitor" components consist of a transistor and zener diode as well as an 8k2 resistor, the 1k pot, a 1k5 resistor, a 150R resistor and a signal diode. The signal diode is actually part of the flasher schema and we discuss its operation later.

As the voltage across the battery increases to 13.4 volts, each resistor in the "voltage detecting network"  will have a voltage drop across it that corresponds to the resistance of the resistor. The diode will have a constant 0.7v across it. The voltage on the wiper of the pot will be about 3.25v and the voltage across the zener will be 10v. This leaves 0.6v between the base and emitter of the Voltage Monitor transistor.

This voltage is sufficient to turn the transistor ON.
When the Voltage Monitor transistor turns ON, it robs the "Turn On" transistor of base-emitter voltage and the schema turns off.

The SCR has only two states: ON and OFF.
During the half-cycle when it is turned on, the battery gets a high pulse of current and the current is only limited by the capability of the plug pack. There are no electrolytics to allow very high pulses of current to be delivered and this is fortunate as the SCR is only a 0.8 amp device, but will endure surges of 10amp for half a cycle.

Whenever the SCR is triggered into conduction during the half cycle of its operation, it remains in conduction until the voltage delivered by the plug pack falls to zero. This is when the SCR turns off. When the plug pack delivers a negative voltage to the top rail and a positive voltage to the lowest rail, the SCR is not triggered into conduction and none of the components in the schema deliver current to the battery. The SCR delivers current for a few half-cycles and then it is turned off for a few cycles. This is how the average current delivered to the battery is controlled.

The schema is designed to deliver about 300 - 400 mA average charge-current. The maximum value is determined by the 1R8 resistors. They do not allow any more than 900mA to flow during a half-cycle and if this current flows, the lower 47u is charged and the lower transistor turns on to prevent the SCR turning on.
When the battery is fully charged, the indicator LED begins to flash.

The flashing is produced by the 2k2 resistor and 47u (connected to the voltage monitor section). When the battery is charging, the 47u is charged via the diode connected to the BC557 transistor and through the 150R and signal diode to the negative of the battery.

When the battery is fully charged, the Voltage Monitor section turns ON and turns off the "Turn ON" section.
This removes the voltage on the positive side of the 47u and the positive side is brought to the negative rail via the 2k2 resistor. This brings down the negative side of the 47u and the 150R resistor is  allowed to drop below the negative rail due to the presence of the diode, as the diode becomes reverse-biased.

This holds the schema in the "off" condition, as the voltage monitor section sees an extra voltage across it and thinks the battery it is "over-charged."



The 47u discharges and the schema turns ON to pump a small burst of current into the battery to keep it charged. This is called "Trickle Mode"  or "Pulse Mode."


HOW TO SET THE POT
Charge a battery and when the voltage reaches 13.4v, adjust the pot so the LED flashes.


DEAD BATTERIES
The schema will not turn on if the voltage of the battery you are charging is less than 4 volts. If you have a good battery that has been totally discharged, you can manually start the charging process by connecting the battery and pressing the button. This will raise the voltage on each cell and the schema will take over in the normal way once the voltage rises more than 4 volts.

SCR: MCR100     
type - 6     400v
current     0.8A
Max current
for half cycle     10A

DONT WASTE YOUR TIME
If you have a battery that does not charge, even after you have pressed the push button, dont waste your time. If it has been standing for more than 6 months in an uncharged state, it will not charge. This charger is ideal in determining if a battery is able to be charged.

Just connect it to the charger and monitor the voltage across the battery. If it remains at less than 8v after 1 hour, the battery is scrap. You can easily test a battery by putting a 12v car globe across the terminals. Even a tail light globe will require a current of more than 1 amp to get it to glow and if the battery cannot deliver this current, it is DEAD.

The only "dead" battery that can be recovered is one that has been connected to equipment and is totally exhausted. The equipment has exhausted the battery. If you charge it within a few weeks, the process of "sulphation" will not have damaged it and it can be fully charged. If the battery is "dead" due to standing for a long time, the chances of recovery are virtually nil.

Sealed Batteries
Sealed batteries have the acid either gelled or put into a sponge-like glass mat. They have the advantage/disadvantage of being completely liquid-tight. They can operate in any position, even sideways or upside down, and will not leak acid. Because the electrolyte moves more slowly, these batteries cannot tolerate high rates of charging or discharging for extended periods, although their thinner plates will allow high rates for a short time. Their sealed construction, which makes them ideal for some limited applications, makes it impossible to check individual cell conditions with a hydrometer. Although these cells are "sealed," they do have vents to prevent pressure build-up in case of gassing. Many PV charge controls will push charging voltage too high for sealed batteries. Premature failure will result due to loss of water vapor. We recommend sealed batteries only in situations where hydrogen gassing during charging cannot be tolerated, or the battery is going to be moved and handled a great deal, or in conditions where the battery needs to fit into unique, tight spaces. Boats, UPS computer power supplies, and remote expeditions are the most common uses. Special lower voltage charge controls must be used with these batteries. Life expectancy is two to five years for most AGM (absorbed glass mat) batteries, and five to ten years for the higher quality, but more difficult to manufacture, gel cell batteries. Most sealed batteries are AGM types.


Here is a Printed Circuit board made by Tom Kelly, one of our readers:


You can clearly see the track-work under the board and it is easy to copy the layout and produce your own board. The board was produced by Tom Kelly.  You can email him for the file so you can make your own PC board.

Or you can buy a PCB from Talking Electronics with overlay and tinned solder-lands for $3.00 plus $3.00 postage

PCB

PARTS LIST
12v SLA Battery Charger
PCB $3.00 plus $3.00 post

2 - 1R8 0.5watt resistors
1 - 150R 0.25 watt resistor
1 - 180R
1 - 560R
1 - 1k5
3 - 2k2
1 - 3k3
1 - 4k7
1 - 8k2
1 - 1k mini trim pot

1 - 1n ceramic
2 - 47u 25v electrolytics

1 - 5mm red LED

4 - 1N4148 signal diodes
1 - 10v 0.25watt zener
1 - BC 547 transistor
2 - BC557 transistors
1 - MCR100-6 SCR
1 - 1m red lead
1 - 1m black lead
2 - alligator clips
1 - 2m very fine solder

1 - SLA Battery Charger PCB

Also required:
1 - 12v AC transformer (500mA AC)
1 - power lead
1 - case


Sourced by: talkingelectronics
Read More..

Tuesday, August 19, 2014

12V fixed voltage power supply circuit diagram

Here this schema diagram is for +12V regulated (fixed voltage) DC power supply. These power supply schema diagram is ideal for an average current requirement of  1Amp. This  schema is based on IC LM7812. It is a 3-terminal (+ve) voltage regulator IC. It has short schema  protection , thermal overload protection.  LM7812 IC is from LM78XX series. The LM78XX series IC is  positive voltage regulator IC for different voltage requirements, for example LM7805 IC is made for 5 volt fixed output voltage . There is LM79XX IC series for negative voltage .

Circuit diagram of 12V fixed voltage power supply

12V

 A transformer(Tx=Primary 230 Volt, Secondary 12 Volt , 1Amp step down transformer) is used to covert 230V to 12V from mains. Here used a bridge rectifier made by four  1N4007 or 1N4003 diode to convert AC to DC . The filtering capacitor 1000uF,25V is used to reduce the ripple and  get a smooth DC voltage. This schema is very easy to build. For good performance input  voltage should be greater than 12Volt in pin-1 of IC LM7812. Use a heat sink to IC LM7812 for safeguarding it  from overheating.

Read More..

Friday, August 15, 2014

12V to 230V Inverter Wiring diagram Schematic

At present we can see electricity has become an essential thing with out electricity it is difficult to lead our life.Free schema Diagrams 4u always try to give you useful things.So today Im going to give you an inverter schema diagram.By using this inverter you can generate 230v AC .Transformer is a network with two 12V secondary windings and must be rated for the maximum load required drive.here we have used MOSFET transistors





Note: 
          # Be careful when you deal with 230V
          # This is not a suitable schema for kids so dont try to test this because 230V is dangerous
Read More..